Series FXE \ FXE M
LIFTING TAILORED SOLUTIONS ModelFXE-M600.50+

FXE-M600.50+

Datasheet
Product Id10610602
Max. Load capacity Flat From15 mm
Max load600 Kg
Clamping surface372 x 52 mm
Max. Operation temperature 80 °C
Breakaway21 kN
Pole Type50+
Poles Q.ty6
Width420 mm
Length95 mm
Height83 mm
Weight20 Kg

FXE-M600.50+

Image
FXEM Product

FXE-M600.50+

Pole Schema 50+
Pole Schema 50+

FXE-M600.50+

Pole Specifications 50+

Pole Type 50+ has a strengthening magnetic system with the same pole size as the pole type 50. This means on poor surfaces, the holding force can be improved, especially if pole extensions are required. With air gap 0, the pole type reaches 50+.

FXE-M600.50+

Downloads

FXE M

Available models
Model Max. Load Poles Magnetic Anchoring surface Weight
From Thikness Load Type Quantity
15 mm 150 Kg 50 2 116 x 52 mm 6 Kg
15 mm 300 Kg 50 4 116 x 116 mm 12 Kg
15 mm 400 Kg 50 4 244 x 52 mm 12 Kg
15 mm 400 Kg 50+ 4 244 x 52 mm 16 Kg
15 mm 500 Kg 50 6 180 x 116 mm 16 Kg
15 mm 600 Kg 50 6 372 x 52 mm 16 Kg
15 mm 600 Kg 50+ 6 372 x 52 mm 20 Kg
15 mm 750 Kg 50 8 244 x 116 mm 20 Kg
15 mm 1000 Kg 50 10 628 x 52 mm 28 Kg
15 mm 1000 Kg 50+ 10 628 x 52 mm 38 Kg
25 mm 1000 Kg 80 4 172 x 172 mm 30 Kg
15 mm 1100 Kg 50 12 372 x 116 mm 32 Kg
15 mm 1600 Kg 50 18 564 x 116 mm 46 Kg
35 mm 1600 Kg 100 4 222 x 222 mm 72 Kg
35 mm 2400 Kg 100 6 342 x 222 mm 104 Kg
25 mm 2500 Kg 80 10 448 x 172 mm 70 Kg
35 mm 3200 Kg 100 8 462 x 222 mm 138 Kg
25 mm 4000 Kg 80 16 724 x 172 mm 107 Kg
35 mm 4800 Kg 100 12 702 x 222 mm 196 Kg
35 mm 7200 Kg 100 18 702 x 342 mm 286 Kg
Safety factor 3 Test Method EN 13155 Max Operating Temperature 80 °C

Complete Range FXE

Lifting Tailored solutions

FXE M

FXE M permanent-electro magnetic modules can be connected to the MCF control unit to create modular lifting systems

FXE Z

The FXE Z magnetic modules have an additional capability to demagnetize the workpiece after handling.

FXE R

The FXE-R line of magnetic modules allows you to lift circular or flat materials.

FXE SPECIAL

Customized solutions for magnetic lifting systems with electropermanent-operated systems.